Thank you for writing to us. One of our executive will reach back to you through your submitted medium. In case there’s an urgency, feel free to connect over WhatsApp for faster response.
Prefer calling? Dial +9108048128582 (International callers) or 08048128582 (Indian callers).
As per ASTM D4217 , DIN 55990- P8
Gel Time Apparatus is used for determination gel time of powder coating or sample at which time it turns into gel on a polished metal surface at specific temperature. Gel time is the time at which the sample turns into gel from solid and it is not able to be used further. Gel time apparatus is made from non corrosive material. The top plate is made up of aluminium and it is provided with a sensor. It has a long lasting heating coil, temperature controller and digital timer display. It is widely used in plastic industries, powder coating.
Abel Flash Point Apparatus.
Electrically operated having Thermostatic control
As per IP 33, 170 & IS 1448 (PT I)
For Determination of flash point of petroleum products and mixture having flash point below 49°C ( 120°F )
The apparatus consists of Brass Cup fitted with test flame arrangement. Stirrer is placed for maual stirring during testing. The Outer Jacket of the water bath is fitted with a stand. Heating is by 500 watts coil heater fitted to the stand. Heating is controlled by Energy Regulator.
Country of Origin : INDIA
ASTM Solvent Distillation Apparatus is used to separate the mixture of liquid solvent and petroleum products.
The appratus determines initial boiling point, final boiling point, dry point , % of residue remains and % of material recovered. It consists of a water bath having outer chamber made of epoxy powdear coated. Inner chamber made of stainless steel with condenser tube, heating unit with regulator for controlling the temperature, measuring cylinder, flask with IP standard and thermometer -10°C to 360°C.
It is widely used in paint and coating industries, oil and solvent, other liquid mixture.
Standard: IS 1448 (P-18), IP 123, ASTM D 86
Package Includes:
ASTM distillation apparatus, flask,measuring cylinder 100 ml,manual and thermometer (-10°C to 360°C)
WATER SPRAY OFF TESTER
As per ASTM D 4049
Water spray off tester evaluates the ability of a lubricating grease to adhere to a metal surface when subjected to a direct water spray under controlled conditions. The percentage of grease sprayed off a stainless steel test panel after a specified period is determined by weight.
- It Conforms to ASTM D4049 specifications
The equipment including spray chamber, delivery system and constant temperature reservoir. It Sprays water at the specified rate and temperature on a test panel coated with sample grease.
To test for water spray resistance, fill reservoir with 8L of tap water and set the temperature comtroller at test temperature. Circulate the water through the system to attain temperature equilibrium and insert the coated test panel in the spray chamber. Adjust water spray to 40psi (276kPa) and continue for 5 minutes.
Water spray system includes 1.3hp positive displacement pump; spray nozzle with snubber fitting: 0-60psi pressure gauge; bypass valve; shut-off and drain valves; and flexible high pressure water lines. Hinged acrylic spray chamber cover is recessed into the chamber housing to insure watertight operation. Standardized grease application fixture coats test panel with the required thickness of sample grease. Uses tap water; does not require water hook-up.
The system includes:
Stainless steel test panel
Grease application fixture
Thermometer holders
Pressure gauge
Salient feature –
Dital Temperature Controller
Unit for temperature accuracy 0.03°C
Temperature range : 35.00 to 150.0°C
Power supply: 230 Volt AC. 1 phase, 50Hz
Country of Origin : India
Disintegration Tester is a solid state instrument designed for the accurate estimation of disintegration time of tablets as per IP/USP standards. The instrument is designed to test two batches of six tablets, simultaneously. The unit is extremely useful for pharmaceutical industries. It is used in quality control and R & D to determine compliance with the disintegration requirement of the tablet and capsule as per USP/BP/IP standards.
Instrument uses the latest microprocessor technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The system has user friendly prompts, which guide you throughout the measurement process.
Specifications:
» Complies with USP, IP specifications
» Extremely useful for pharmaceutical labs
» Highly Accurate and Easy to Operate
» Baskets UP & DOWN movement as per IP/USP Specifications
» 20 x 4 Line Alphanumeric LCD with Backlit
» 15 Soft Touch Membrane Type Keys
The Digital Bulk Density Apparatus is a microprocessor based instrument designed to study the packing down of powder beds of different pharmaceutical & chemical powders and gives accurate & repeatability of the result.
Bulk Density is an essential test required in the process of Tablet manufacturing, capsules filling and cosmetics manufacturing as important part of quality control program. 4 digit microprocessor based Pre-set counter provided to set exact no of strokes. This feature eliminates the tedious calculation of Timer Mode. A common holder for both the cylinder drops down smoothly from the specified height. Easy to lock cushioned holders are provided to hold the cylinder. In power failure, the non-volatile memory of the microprocessor remember the last mode of operation, and complete the test after the power supply is resumed. It has the following features:
Specifications :
» Display: Digital 12 mm Red LED
» Speed range - 30RPM
Mechanical Timer/Digital counter as per requirement.
Demulsion Bath
As per ASTM D1401, DIN51599
Demulsion Bath or Demulsibility Bath is used for determination of ability of a lubricating oil to separate from water and resist emulsification. This is one of the most important performance characteristic for Lubricating oil for applications involving water contamination and turbulence. Water separability is determined by stirring equal volume of water and sample together at a controlled temperature to form an emulsion and observing the time required for separation of the emulsion to occur. This method is suitable for petroleum oils and synthetic fluids.
Construction - Double Walled Construction with toughened glass observation window.
Circulation system – Heavy duty capacitor run motor with stirrer to help maintain uniform temperature across bath media.
Heater – immersion heater fitted to help achieve above ambient temperature. Heater connected to PID output heater wiring done using Teflon coated cable
Temperature controller & instrumentation – fully automatic microprocessor based PID controller having feather touch key board. Display indicating temperature with resolution of 0.01& the controller is having splash proof membrane with PT -100 sensors.
Features
Illumination from back side.
4 Nos. Herschel Emulsifier.
Stirrer can be easily moved to each test position instead of moving the samples.
Digital temperature controller with speed and timer
Timer stops the stirring on completion of set time i.e. 5 minutes automatically with alarm.
Temperature: Ambient to 100°C, ± 0.5°C.
Speed up to 1500 rpm, ± 15 rpm
Power supply: 120 V / 230 Volts , Single Phase AC , 50/60 Hz
Cold Filter Plugging Point Apparatus as per ASTM D6371; IP 309, 419; EN 116
The Cold Filter Plugging Point (CFPP) Apparatus determines low temperature flow characteristics of diesel fuels, gas oils and other distillate fuels. It comprises a 4 liter dry ice bath (Dewar Flask) and a CFPP test insert connected via a three way cock to a UKAS certified digital manometer and two 5 litre pressure equalising vessels
Acrylic Body Rotameters are machined from clear acrylic block. They are designed to give maximum accuracy in visibility and ruggedness.
The floats are made from Stainless Steel, PVC and other non corrosive plastics and offered as per the process requirement. The needle valve is provided for accurate flow control. It is designed to give accuracy of within 1.5 to 2 % at full scale. The higher accuracy can be made on specific requirement.
The Rotameter can be fitted with Top / Bottom or rear connections as per specific requirement. The Rotameters are ideal for direct panel mounting because of their clear modular appearance, online installation is also possible.
Inclined Tube Manometers are used for accurate measurement of low pressure viz. draft and very low pressure differentials.
Inclined Tube Manometers spread the pressure measurement range over a relatively long scale.
Inclined Tube manometers are made in Acrylic Body / Glass Tube housed in Metal Casing.
Available Sizes : 0 - 10 mm wc to 0 – 500 mm wc
Application : Ideal for filter applications, Ventilation and air conditioning systems and Laminar Air Flow Systems
As per ASTM D3527 ,D4290, D4950. The equipment is used for testing of grease for evaluating its life performance by testing at high-temperature.
The equipment consists of a modified front wheel hub-spindle-bearings assembly housed in a constant temperature oven and coupled to a ¼ Hp variable-speed drive motor. It Control the test functions automatically and provides continuous digital display of motor torque, rpm, chamber temperature, spindle temperature, time cycle and elapsed time. Test parameters outside of ASTM specifications can be selected by the operator for in-house testing. Automatically terminates test and displays elapsed on-cycle hours when grease deterioration causes drive motor torque to increase to the calibrated end point. A built-in thirty second time delay circuit prevents erroneous test terminations due to momentary surges in motor torque at the beginning of the on-cycle. Insulated constant temperature oven is equipped with a 1200W heater and balanced 1/20 hp circulation fan for efficient heat distribution. Sliding access doors and a movable platform that swings the drive motor out of the way provide easy access to the spindle assembly. Modified steel spindle and hub assembly conforms to all critical 1971 Chevy II dimensions and is fitted with thermocouple, bearing thrust loading device and anodized aluminum grease collector. All controls and monitors are housed in a separate cabinet.
Digital controls and displays:
Timer : on/off cycle and real time
Motor rpm : 0-1725 rpm
Motor Torque: current draw
Elapsed Time: 9999.9 hr.
Maximum Temperature: 177°C
Electrical Requirements
220-240V 50Hz, Single Phase, 7A
Included Accessories
Thermocouples (2)
Thermometer holder
Bearings (1 set)
Grease Packer Assembly
Bearing Installation/Removal Tools:
Bearing installer, small and large bearing cup removers, bearing cup installer, bearing puller and spindle wrenches (pins)